weberproof TPO
Release date
Package: 20m x 1m (20m2/roll) (edge welding)
Total Thickness: ≥ 1.2 ; 1.5 ; 1.7 ; 2.0 (mm)
Adhesive color: White
SELF-ADHESIVE WARTERPROOFING MEMBRANE WEBERPROOF TPO
PRODUCT FEARTURES:
- Designed to prevent undesired adhesion upon contact during construction, Weberproof TPO waterproofing membrane ensures excellent adhesion, complete waterproofing without water channeling.
- The softness and flexibility of the membrane allow it to fit tightly to the surfaces at joint locations, enhancing resistance to both high and low temperatures, and providing excellent chemical corrosion resistance.
- The butyl adhesive layer is aging resistant and fully waterproof, ensuring a long service life in underground or complex conditions.
SCOPE OF USE
Technical basements and diaphragm walls in confined construction spaces. Mining tunnels.
Weberproof TPO self-adhesive waterproofing membrane consists of a main TPO layer a butyl self-adhesive layer, and a particulate layer that serves to protect the adhesive layer. The multiple-layer waterproofing membrane is designed to blend resistance to low temperature, heat aging, and chemical corrosion with adhesive strength and watertightness.
After the waterproof membrane is paved, the structural concrete can be casted directly to the treated surface. Under gravity, the liquid concrete compound will form linkage with the butyl adhesive layer of the membrane. This combines physical adsorption with chemical reactions during the cement curing process, bonding firmly the waterproofing membrane and the structural concrete to achieve a reliable and full adhesion.
Storage:
Store at temperatures below +40°C
Store indoors or on shelves under cover.
Do not stack pallets on top of each other.
Composition: Main TPO substrate, self-adhesive butyl layer, and adhesive protective sand layer.
Property | Result | Test method |
---|---|---|
Roll dimensions | 1m x 20m (width x length) | - |
Tensile Strength | ≥ 8 Mpa | ASTM D412-16 |
Elongation at break | ≥ 650 % | ASTM D412-16 |
Tear resistance | ≥ 100 N | ASTM D1004-13 |
Waterproof capability under hydrostatic pressure | ≥ 71 m | ASTM D5385 |
Resistance to puncture | ≥ 700 N | ASTM E154/E154M-08a |
Peel adhesion of concrete | ≥ 2 N/mm | ASTM D903-98 |
- If Weberproof TPO membrane is pre-applied to concrete wall surfaces, the formwork must not be removed until the concrete wall is at least 7 days old.
- Overlap lines should be welded in accordance with technical requirements, tight and free from any errors such as twisting or wrinkling.
- The allowable deviation for the overlap section is -10 mm.
- The width of overlap sections on the long side, short side and other joint locations must not be less than 40mm.